ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING  |  NOTES FROM A 30-YEAR INDUSTRY VETERAN

AP1000 Steam Generator Tube Sheet Surfacing: Cold Crack Analysis and Mitigation

Literature Overview and Context

This paper by Zheng Zhangli et al. from State Nuclear Power Engineering Company addresses a critical problem in nuclear power plant construction: cold cracking in the tube sheet surfacing of AP1000 steam generators. The tube sheet is a massive forging that requires a thick corrosion-resistant surfacing layer on the primary side. Cold cracking during or after surfacing is a serious quality issue that can delay the project and compromise the integrity of the component.

The paper is published in a Chinese nuclear power engineering journal. The authors analyze the root causes of cold cracking from four perspectives: base metal welding characteristics, hydrogen effects, welding process, and residual stress. They then propose improvements in forging procurement, welding control, and surfacing process.

Root Cause Analysis

Base Metal Welding Characteristics

The tube sheet is typically made of a low-alloy steel forging, such as SA-508 Gr.3 Cl.1 or similar. This material has a high carbon equivalent, which increases its susceptibility to cold cracking. The welding characteristics include:

Hydrogen Effects

Hydrogen is the primary cause of cold cracking. The sources of hydrogen include:

Hydrogen diffuses into the HAZ and accumulates at stress concentrations. When the local hydrogen concentration exceeds a critical value, cracking initiates. The cracking is typically delayed — it occurs hours or days after welding, which makes it difficult to detect.

Welding Process

The surfacing process for the tube sheet is typically a strip cladding process using a submerged arc welding (SAW) or electroslag welding (ESW) method. The process parameters affect the cooling rate and the hydrogen content:

Residual Stress

The surfacing process creates a tensile stress field in the deposited layer and the HAZ. When combined with hydrogen and a susceptible microstructure, the residual stress can trigger cold cracking. The stress is highest at the edges of the clad layer and at the interface between the clad and the base metal.

Proposed Improvements

Forging Procurement

Improvement Rationale
Specify lower carbon equivalent Reduces hardenability and crack susceptibility
Require vacuum degassing Reduces hydrogen content in the forging
Specify grain size control Refines the grain, improves toughness
Require ultrasonic testing Detects internal defects before machining

Welding Control

Improvement Rationale
Strict preheat control Prevents martensite formation in the HAZ
Interpass temperature monitoring Ensures consistent cooling rate
Post-weld heat treatment (PWHT) Relieves residual stress, tempers martensite
Hydrogen bake-out Removes hydrogen from the weld before PWHT
Controlled cooling after welding Prevents rapid cooling that promotes cracking

Surfacing Process

Improvement Rationale
Use low-hydrogen consumables Reduces hydrogen input
Optimize heat input Balances cooling rate and deposition rate
Use multiple layers Reduces the stress in each layer
Control layer thickness Prevents excessive buildup and stress

Engineering Practice Implications

Application to Nuclear Power Plant Construction

This paper is directly relevant to the AP1000 steam generator fabrication. The tube sheet is one of the most critical components in the steam generator, and cold cracking during surfacing is a serious quality issue. The proposed improvements are practical and can be implemented in a fabrication shop.

Lessons for Other Applications

The lessons from this paper apply to any thick-section low-alloy steel component that requires surfacing. The combination of high carbon equivalent, hydrogen, and residual stress is a recipe for cold cracking. The countermeasures — preheat, PWHT, low-hydrogen consumables, and controlled cooling — are standard practice in the industry, but they must be rigorously implemented.

Quality Control

For a critical component like a tube sheet, the quality control must include:

  1. Pre-weld inspection — verify the forging quality, surface condition, and preheat temperature.
  2. In-process monitoring — record the interpass temperature, heat input, and welding parameters.
  3. Post-weld inspection — perform NDT (UT, PT, RT) after a delay of at least 24 hours to allow hydrogen-induced cracking to develop.
  4. PWHT verification — confirm the heat treatment parameters and the resulting hardness and toughness.

Study Insights and Reflections

This paper is a good example of root cause analysis applied to a real manufacturing problem. The authors correctly identify the four contributing factors: base metal characteristics, hydrogen, welding process, and residual stress. The proposed improvements address each factor in a systematic way.

The key lesson is that cold cracking is a multi-factor problem. It is not enough to simply reduce the hydrogen content or increase the preheat temperature — all factors must be addressed together. A welding procedure that works in the laboratory may fail in production if the base metal is different or the hydrogen content is higher.

For the shop floor, the practical takeaway is to treat cold cracking as a process control issue, not a metallurgical mystery. The control points are well known: preheat, interpass temperature, hydrogen control, and PWHT. If these are rigorously controlled, cold cracking can be prevented.