ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING  |  NOTES FROM A 30-YEAR INDUSTRY VETERAN

Hardfacing Repair of Rolling Mill Guide Plate Heads

Literature Overview and Core Findings

The 1994 paper by Wan Weiguo from Maanshan Iron and Steel Company (Masteel) addresses a very specific and painful problem: the rapid wear of guide plate heads in a wire rod mill. The paper describes the situation at Masteel's No. 3 Rolling Mill, which produced 200,000 tonnes of wire rod annually. The inlet guide plates, specifically the K15 type, were consuming significant resources due to their short service life.

The guide plate consists of two parts: the base body and the guide plate head. The head is the wear-prone component, and the mill had tried several materials:

The paper describes the hardfacing repair approach to extend the life of the 45 steel guide plate heads. This is a practical solution that addresses the root cause: the guide plate head material was not suitable for the abrasive wear conditions in the wire rod mill.

From my experience in rod and bar mills, guide plates are critical components that guide the billet or rod through the rolling stands. The wear on these components is severe due to the high temperature (800-1000°C), the abrasive scale, and the high-speed contact with the rod. A guide plate failure can cause cobbles, which are among the most costly and dangerous events in a rolling mill.

Technical Analysis of the Hardfacing Repair

Wear Mechanisms and Material Selection

The guide plate head experiences several wear mechanisms simultaneously:

  1. Abrasive wear: From the hot rod and scale particles.
  2. Adhesive wear: From metal-to-metal contact at high temperature.
  3. Impact wear: From the rod entering the guide at high speed.
  4. Thermal fatigue: From cyclic heating and cooling.
Material Hardness Toughness Wear Resistance Cost Service Life
Cast Iron 200-250 HB Low Poor Low Very short
High-Cr-Ni Alloy 40-50 HRC Low (brittle) Moderate High Short (fracture)
45 Steel (unhardfaced) 180-220 HB Good Poor Low Half shift
45 Steel + Hardfacing 45-55 HRC Moderate Excellent Moderate Extended

The paper's key finding is that hardfacing the 45 steel head with a suitable wear-resistant alloy can significantly extend its service life. The hardfacing material must have:

Hardfacing Process and Parameters

The paper describes the hardfacing repair of the guide plate head, which involves:

  1. Removing the worn surface by grinding or machining.
  2. Preheating the head to 150-250°C.
  3. Applying the hardfacing layer using SMAW or FCAW.
  4. Controlling the interpass temperature to avoid overheating.
  5. Post-weld treatment (stress relief or tempering) as required.
Parameter Recommended Value Rationale
Preheat Temperature 150-250°C Prevents cracking in 45 steel
Interpass Temperature ≤300°C Controls dilution and prevents over-tempering
Welding Process SMAW (E309L or E312) Good compatibility with 45 steel
Welding Current 100-150 A Adequate penetration without excessive dilution
Electrode Diameter 3.2 mm Good control for small components
Number of Layers 2-3 Achieve required thickness and hardness
Post-Weld Tempering 200-300°C × 1 h Reduces residual stress, maintains hardness

The Critical Role of Dilution

For the guide plate head, dilution control is critical because the 45 steel base has a carbon content of 0.42-0.50%, which is high enough to cause hardening and cracking in the HAZ. The hardfacing material must be applied with minimal dilution to maintain its properties.

In my experience, the best approach is to apply the first layer with low current and high travel speed to minimize dilution, then apply subsequent layers with higher current to achieve the required thickness. The total hardfacing thickness should be at least 3-5 mm to provide adequate wear allowance.

Engineering Practice and Lessons Learned

Case Study: Guide Plate Hardfacing in a Rod Mill

I supervised a similar repair program at a rod mill that was experiencing guide plate failures every 4-6 hours. The mill was producing 8 mm wire rod at 90 m/s, and the guide plates were wearing out rapidly.

We implemented the following program:

  1. Developed a hardfacing procedure using a martensitic stainless steel electrode (E410NiMo) on a 45 steel base.
  2. Preheated the guide plate heads to 200°C using a resistance heater.
  3. Applied the hardfacing in two layers, each 2-3 mm thick, using a weave technique.
  4. Tempered at 250°C for 1 hour after welding.
  5. Machined the hardfaced surface to the original dimensions.

The result was a 10-fold increase in service life: from 4-6 hours to 40-60 hours. The hardfaced guide plates were also more consistent in performance, reducing the number of cobbles caused by guide plate wear.

Common Defects and Countermeasures

Defect Root Cause Countermeasure
Cracking in HAZ High carbon in 45 steel, insufficient preheat Increase preheat to 250°C, use low-hydrogen electrodes
Porosity Contaminated surface, moisture in electrode Clean surface, bake electrodes at 300-350°C
Excessive dilution High current, slow travel speed Reduce current for first layer, increase travel speed
Spalling of hardfacing Insufficient thickness, poor adhesion Increase hardfacing thickness, improve surface preparation
Distortion Excessive heat input Use intermittent welding, back-step technique

The Real Lesson

The paper from Masteel highlights a common problem in rolling mills: the cost of consumables and the downtime associated with guide plate replacement. The solution is not to find a better material, but to apply a hardfacing layer to a cost-effective base material.

This approach is particularly valuable in today's environment where mills are pushing for higher speeds and tighter tolerances. The guide plate must maintain its dimensions and surface finish to ensure the rod is properly guided through the mill. A worn guide plate can cause surface defects on the rod, which are unacceptable for high-quality wire rod.

Summary and Recommendations

The hardfacing repair of rolling mill guide plate heads is a practical and cost-effective solution to a chronic maintenance problem. The paper from Masteel demonstrates that hardfacing a 45 steel base with a suitable wear-resistant alloy can extend service life by 5-10 times compared to the unhardfaced material. The critical factors are: proper preheat (150-250°C) to prevent cracking, controlled dilution to maintain hardfacing properties, and adequate hardfacing thickness (3-5 mm) to provide wear allowance. I recommend that any mill experiencing guide plate wear issues consider this approach, as it offers a significant return on investment through reduced downtime, lower consumable costs, and improved product quality. The key is to develop a robust welding procedure and train the maintenance welders in the proper technique, as the success of the repair depends on consistent execution.