ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING  |  NOTES FROM A 30-YEAR INDUSTRY VETERAN

Ni60 Plasma Cladding on Copper Substrate: Microstructure, Hardness, and Application in Copper Launders

Literature Overview and Core Findings

The paper by Wang Chao, Zhu Xiebin, and Cheng Jingqing from Anhui Polytechnic University addresses a specific industrial problem: the wear and erosion of copper launders (出铜槽) in non-ferrous metallurgy. These launders carry molten copper and copper slag, causing severe erosion of the copper surface. The solution is to apply a Ni60 nickel-based alloy coating on the copper substrate using plasma cladding.

The key findings are:

  1. The Ni60 coating achieves good metallurgical bonding with the copper substrate.
  2. The coating microstructure shows a clear gradient, with a dendritic network structure typical of rapid solidification.
  3. The coating hardness reaches 650 HV0.1, significantly higher than the copper substrate.
  4. The Ni60 melting point (1400°C) is higher than copper (1083°C), providing better resistance to high-temperature erosion.

Technical Interpretation and Process Analysis

The Ni60 Alloy System

Ni60 is a nickel-based self-fluxing alloy with the following typical composition:

Element Content (wt%) Function
Ni Balance Matrix, corrosion resistance
Cr 15-20 Oxidation resistance, hard phase formation
B 3-4 Fluxing agent, hard phase formation (Ni3B)
Si 3-4 Fluxing agent, hard phase formation (Ni3Si2)
Fe < 5 Impurity, reduces properties
C < 1 Carbide formation

The boron and silicon serve dual purposes: they lower the melting point (making the alloy self-fluxing) and form hard intermetallic phases (Ni3B, Ni3Si2) that provide wear resistance. The chromium provides oxidation resistance and forms chromium carbides and borides that further enhance hardness.

The Challenge of Copper Substrate

Copper presents unique challenges for cladding:

  1. High thermal conductivity. Copper conducts heat rapidly, causing the molten pool to solidify quickly. This can lead to porosity and lack of fusion if the heat input is insufficient.
  2. High thermal expansion. Copper expands significantly when heated, causing distortion and residual stress.
  3. Low melting point. Copper melts at 1083°C, while Ni60 melts at 1400°C. The temperature difference creates a steep thermal gradient that can cause cracking.
  4. Poor wettability. Molten Ni60 does not wet copper as well as it wets steel, making fusion more difficult.
  5. Oxygen affinity. Copper readily forms oxides, which can cause lack of fusion if the surface is not properly cleaned.

Microstructure Development

The paper describes a dendritic network structure with typical rapid solidification characteristics. This is consistent with the high cooling rate of plasma cladding, where the molten pool is small and the substrate acts as a heat sink.

The microstructure gradient is important:

The dendritic network of Ni3B and Ni3Si2 hard phases in a nickel matrix provides the wear resistance. The hardness of 650 HV0.1 is a result of this composite structure.

Integration with Engineering Practice

Copper Launder Application

Copper launders are critical components in copper smelting. They carry molten copper at temperatures around 1100-1200°C from the furnace to the casting area. The copper surface is continuously eroded by the flow of molten metal and slag.

The traditional materials for launders were graphite and refractory materials. These have poor mechanical strength and are difficult to maintain. Copper launders offer better mechanical properties but suffer from erosion. The Ni60 coating provides:

Real-World Experience with Copper Launders

In my experience with copper smelting operations, the main challenges with copper launders are:

  1. Thermal cycling. The launder is heated and cooled repeatedly, causing thermal fatigue. The Ni60 coating must have sufficient ductility to accommodate this.
  2. Slag erosion. Copper slag is abrasive and chemically aggressive. The coating must withstand both mechanical erosion and chemical attack.
  3. Repair and maintenance. When the coating fails, it must be re-clad. The copper substrate may be damaged, requiring repair before re-cladding.

Process Parameters for Ni60 on Copper

Parameter Recommended Range Notes
Plasma current 80-120 A Lower than steel to prevent excessive melting
Arc voltage 20-25 V Standard plasma arc voltage
Powder feed rate 15-25 g/min Adjusted to achieve desired thickness
Travel speed 60-100 mm/min Slower for better fusion
Shielding gas Ar, 10-15 L/min High purity required
Preheat 100-200°C Reduces thermal gradient
Interpass temperature ≤ 150°C Prevents overheating

The lower current compared to steel is necessary because copper's high thermal conductivity means that even moderate currents can cause excessive melting and dilution.

Key Questions and Reflections

The Dilution Problem on Copper

Dilution of Ni60 with copper is a serious concern. Copper in the nickel matrix degrades the hardness and corrosion resistance. The dilution rate must be kept below 5-10% for optimal performance.

However, copper and nickel form a continuous solid solution, so there is no brittle intermetallic formation. This is an advantage over steel substrates, where iron-nickel intermetallics can form. The challenge is purely one of maintaining the Ni60 composition.

The Porosity Problem

Porosity is a common defect in cladding on copper. The causes include:

  1. Hydrogen. Copper has high hydrogen solubility when molten, but low solubility when solid. Hydrogen can be absorbed from moisture in the powder or shielding gas.
  2. Oxides. Copper oxides can be trapped in the molten pool, causing porosity.
  3. Rapid solidification. The high cooling rate can trap gas bubbles before they escape.

The solution is to:

The Cracking Problem

Cracking can occur due to the thermal expansion mismatch between Ni60 and copper. The coefficient of thermal expansion for copper is 17×10⁻⁶/°C, while for Ni60 it is approximately 14×10⁻⁶/°C. This difference creates tensile stress in the coating during cooling.

The solution is to:

Study Insights and Implications

This paper demonstrates the viability of Ni60 plasma cladding on copper for high-temperature erosion applications. The key insights are:

  1. Metallurgical bonding is achievable. The paper shows good bonding between Ni60 and copper, which is the foundation for any successful coating.
  2. The microstructure gradient is beneficial. The gradient from fine dendrites at the interface to coarser structures near the surface provides a transition in properties that reduces stress concentration.
  3. Hardness is significantly improved. The 650 HV hardness is more than five times that of copper, providing excellent erosion resistance.
  4. The melting point advantage is crucial. Ni60's higher melting point means it can withstand higher temperatures than copper without softening.

The practical implications for copper launder applications are clear: Ni60 cladding can significantly extend the service life of copper launders, reducing maintenance costs and downtime.

Reference Value and Outlook

For engineers in non-ferrous metallurgy, this paper provides valuable data on the feasibility and process parameters for Ni60 cladding on copper. The application to copper launders is a specific example of a broader principle: using high-performance coatings on copper components to extend their service life in aggressive environments.

Looking forward, the industry is exploring:

The veteran's rule for cladding on copper: "Copper is a forgiving substrate in some ways and unforgiving in others. It accepts metallurgical bonding readily, but it steals your heat and hides your porosity. Control the heat input, and you control the outcome."