ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING  |  NOTES FROM A 30-YEAR INDUSTRY VETERAN

Analytical Calculation Method for Temperature Effects of Concrete-Filled Steel Tube Arches

Introduction and Structural Context

Concrete-filled steel tube (CFST) arches are a popular structural form for bridges and large-span structures, combining the high strength of steel with the excellent compressive properties of concrete. The steel tube provides confinement to the concrete core, which enhances the concrete's compressive strength and ductility, while the concrete core prevents the steel tube from buckling inward. However, CFST arches are susceptible to temperature effects, particularly in regions with significant diurnal temperature variations or in cases where the structure is exposed to direct sunlight.

The temperature effects on CFST arches are complex, as the steel and concrete components have different thermal expansion coefficients and thermal conductivities. This leads to a non-uniform temperature distribution across the cross-section, which in turn generates internal stresses and deformations. The analytical calculation of these effects is essential for the design and assessment of CFST arches, as the temperature-induced stresses can be significant and may even exceed the stresses from live loads in some cases.

Analytical Model and Calculation Method

The literature on this topic presents an analytical method for calculating the temperature effects on CFST arches, based on the theory of elasticity and the principles of structural mechanics. The method accounts for the non-uniform temperature distribution across the cross-section, as well as the different material properties of the steel and concrete.

The analytical model is based on the following assumptions:

  1. The temperature distribution across the cross-section is linear, which is a reasonable approximation for thin-walled steel tubes.
  2. The steel tube and the concrete core are in perfect bond, so that there is no relative slip between the two materials.
  3. The material properties of the steel and concrete are linear elastic and temperature-independent.
  4. The arch is treated as a two-dimensional structure, with the temperature effects acting in the plane of the arch.

The temperature-induced stresses are calculated using the following equations:

Component Stress Calculation Remarks
Steel tube σ_s = E_s (α_s ΔT - ε_0) E_s is the elastic modulus of steel
Concrete core σ_c = E_c (α_c ΔT - ε_0) E_c is the elastic modulus of concrete
Axial strain ε_0 = (A_s E_s α_s + A_c E_c α_c) ΔT / (A_s E_s + A_c * E_c) A_s and A_c are the cross-sectional areas

The key parameter in the calculation is the temperature difference ΔT, which is the difference between the actual temperature of the component and the reference temperature at which the structure is assumed to be stress-free. The temperature difference is not uniform across the cross-section, and the method accounts for this by using a linear temperature gradient.

Application to Engineering Practice

The analytical method has been applied to a number of practical cases, including the design of a CFST arch bridge with a span of 120 meters. The results showed that the temperature-induced stresses in the steel tube and the concrete core can be significant, particularly in the summer months when the temperature difference between the steel and concrete can reach 20–30 °C.

Case Temperature Difference (°C) Steel Stress (MPa) Concrete Stress (MPa) Deflection (mm)
Winter 10 15 3 5
Summer 30 45 9 15
Extreme 50 75 15 25

The results indicate that the temperature-induced stresses in the steel tube can reach up to 75 MPa, which is approximately 20% of the design strength of typical structural steel. This is not negligible and must be accounted for in the design. Additionally, the temperature-induced deflection can reach up to 25 mm, which may affect the serviceability of the structure.

The analytical method also allows for the calculation of the temperature-induced bending moments and shear forces in the arch, which are important for the design of the arch ribs and the supporting foundations. The method is particularly useful for the preliminary design stage, where a quick estimate of the temperature effects is needed.

Comparison with Numerical Methods

The analytical method has been validated against more sophisticated numerical methods, such as finite element analysis. The comparison showed that the analytical method provides results that are within 5% of the numerical results, which is acceptable for engineering purposes. The main advantage of the analytical method is its simplicity and speed, which makes it suitable for preliminary design and for checking the results of more detailed analyses.

However, the analytical method has some limitations. It assumes a linear temperature distribution, which may not be accurate for thick-walled steel tubes or for cases where the temperature gradient is non-linear. Additionally, the method does not account for the effects of creep and shrinkage in the concrete, which can be significant in the long term. For these cases, a more detailed numerical analysis is required.

Study Insights and Reflections

The analytical method for calculating temperature effects on CFST arches is a valuable tool for the design engineer. It provides a quick and accurate estimate of the temperature-induced stresses and deformations, which is essential for ensuring the structural integrity of the arch. The method is particularly useful for the preliminary design stage, where the designer needs to assess the feasibility of the structure and to identify the critical load cases.

For the steel pipe manufacturer, the temperature effects on CFST arches have direct implications for the selection of the steel tube. The steel tube must be able to withstand the temperature-induced stresses without yielding or buckling. This requires a thorough understanding of the material properties and the structural behavior of the arch. Additionally, the manufacturer must ensure that the steel tube is properly designed to provide adequate confinement to the concrete core, which is essential for the composite action.

In conclusion, the analytical calculation method for temperature effects on CFST arches is a practical and reliable tool for the design and assessment of these structures. The method accounts for the non-uniform temperature distribution and the different material properties of the steel and concrete, and it provides results that are in good agreement with more detailed numerical analyses. The method is particularly useful for the preliminary design stage, and it can be used to identify the critical load cases and to ensure the structural integrity of the arch.