Eccentric Compression Behaviour of Square Steel Tube High-Strength Concrete Short Columns with an Internal CFRP Circular Tube

Background and Why This Paper Matters

I have spent thirty years watching steel and concrete try to work together, and I can tell you that the interface between the two is where most of the trouble starts. This paper from Shenyang Jianzhu University addresses a real deficiency in square steel tube concrete columns: the flat faces of the square tube provide less confinement to the concrete core than a circular tube does, and under eccentric compression the concrete tends to spall and the tube wall tends to bulge outward. The authors propose a novel solution by placing a CFRP (carbon fibre reinforced polymer) circular tube inside the square steel tube, filling the annular space with high-strength concrete, and then testing the composite under eccentric loading. The CFRP tube acts as an internal confining element, actively restraining the lateral expansion of the concrete core and improving the ductility of the section.

Core Findings and Technical Interpretation

The experimental programme involved fabricating specimens by winding CFRP around a PVC mould tube, placing this inside the square steel tube, and casting high-strength concrete into the remaining space. After curing, the specimens were tested under eccentric compression on a 500 kN testing machine. The key results are summarised in the table below.

Parameter Observed Effect Quantitative Result
Eccentricity ratio Increase in eccentricity reduces load capacity Average increase of 7.5% in eccentricity ratio caused a 20% drop in bearing capacity
Steel ratio (steel tube wall thickness) Higher steel ratio increases capacity Average increase of 1 mm in tube wall thickness raised capacity by 13.6%
Number of CFRP layers More CFRP layers improve capacity Each additional CFRP layer increased capacity by approximately 10%
Boundary eccentricity ratio Transition between large and small eccentricity Determined to be 0.3, consistent with conventional steel tube concrete columns
Neutral axis position Shifts toward the loading side as load increases For the same eccentricity, the neutral axis remained within a small range, moving toward the loading side with increasing eccentricity

The authors also plotted load-strain curves and analysed the Poisson's ratio variation of the composite materials under eccentric load. They found that the composite section generally conforms to the plane section assumption, which is a critical validation for any design model based on strain compatibility. The CFRP provides high strength but limited ductility, so the overall ductility of the composite column is governed by the steel tube and the concrete, with the CFRP contributing primarily to confinement and peak capacity.

Practical Implications for Manufacturing and Construction

From a fabrication standpoint, this composite column introduces several challenges that a plant engineer must consider. The CFRP tube must be manufactured to precise dimensional tolerances so that it fits within the square steel tube with a uniform annular gap for concrete placement. The winding process using a PVC mould is a laboratory technique; scaling this to production would require mandrel-based filament winding with controlled fibre orientation and resin content. The concrete must be of high flowability to fill the narrow annular space without segregation or voids, which means careful mix design and possibly the use of self-compacting concrete.

The confinement mechanism is the key to the improved performance. The square steel tube provides external confinement, but its flat faces are less effective than a circular tube. The internal CFRP tube compensates for this by providing internal confinement to the concrete core, effectively creating a doubly confined section. This is a clever concept, but it introduces a question of constructability: how do you ensure the CFRP tube stays concentric during concrete placement? In practice, this would require spacers or a temporary internal formwork system.

Standards, Quality Control, and Site Considerations

There is no existing standard that directly covers this composite section. The design would need to follow the principles of JGJ 138-2016 (Code for Design of Composite Structures) for the steel tube concrete portion, supplemented by CFRP design guidance from GB 50608 (Technical Code for Infrastructure Application of FRP Composites) or similar. The boundary eccentricity ratio of 0.3 is consistent with conventional steel tube concrete, which suggests that existing design methods for determining the failure mode (small versus large eccentricity) can be applied with minor modifications.

Quality control on site must focus on three critical aspects: the integrity of the CFRP tube (no delamination or fibre breakage during handling and placement), the complete filling of the annular concrete gap (verified by ultrasonic testing or core drilling), and the bond between the steel tube, concrete, and CFRP. The last point is particularly important because the composite action relies on the transfer of shear stresses across the interfaces. Any debonding would significantly reduce the confinement effect.

Key Lessons and Reflections

This paper is a good example of how a structural concept can be validated through careful experimentation. The authors have quantified the effects of the three main variables (eccentricity, steel ratio, and CFRP layers) and established a clear failure mode transition. However, I have some reservations about the practical application. The cost of CFRP is significant, and the manufacturing complexity of placing an internal tube within a steel tube and then filling the annulus with high-strength concrete is substantial. The 10% capacity increase per CFRP layer is attractive, but it must be weighed against the added material and labour costs.

In my experience, composite columns are most economical when the steel tube is used as permanent formwork and the concrete is placed by pumping. The internal CFRP tube would complicate this process, as it would need to be installed before concrete placement and would obstruct the view of the concrete surface. This is a concept that works well in a laboratory but may struggle to find widespread adoption in the field unless a simpler fabrication method is developed.

Conclusion

The paper demonstrates that an internal CFRP circular tube can effectively improve the eccentric compression behaviour of square steel tube high-strength concrete columns, with a clear trade-off between increased capacity and increased complexity. The boundary eccentricity ratio of 0.3 provides a useful design reference, and the observed plane section behaviour validates the use of strain compatibility in analysis. For engineers considering this system, the practical challenges of fabrication, concrete placement, and quality assurance must be addressed before this concept can move from the laboratory to the construction site. The research is a solid contribution to the field of composite structures, and it highlights the importance of confinement in improving the ductility and capacity of concrete-filled steel tubes.